Appearance : LED light
Current Output Range : 0~600A DC current
Voltage Output : 0V - 10kV
Standard : IEC 60736
Usage : energy meter calibration, lab research
Support : Ripple test
Storage Temperature : -20-70°C
Outer Casing : aluminum alloy
Frequency Range : 45-65Hz
Test Object : ring main unit (RMU)
Output Power : 1000VAC
Ac Frequency Range : 0.001-5KHz
Accuracy : 0.05%
Output Range : 0~250A-AC
6-In-1 DC Energy Meter Testing Equipment For Testing Of DC Energy Meter
The YC-9600T6/9100T6/YC-2015Z DC energy meter test instrument is a DC energy meter test instrument that meets the requirements of GB/T 33708-2017, Q/GWD1826-2013, and Q/GDW 1825-2013. It has the following features:
The technical data of YC-9600T6/9100T6/YC-2015Z DC energy meter test instrument are as follows:
DC engery test bench | |
Meter under positions | 1~ 6 |
six-way dc voltage output | |
Quantity limit | 0 ~ 1000V (MAX :1150V ) |
gear | 60V ,500V ,1000V |
accuracy | 0.02% class |
maximumoutput | 30W |
One-way DC current output | |
Quantity limit | 600A |
gear | 1mA ,5mA ,20 mA ,50 mA ,200 mA ,1 A ,5 A , 10 A , 20 A ,60 A ,100 A ,500 A |
accuracy | 0.02% class |
capability | port voltage is greater than 3V |
six-way indirect current output | |
Quantity limit | 0~5V |
gear | Supports 2 .5mV, 20 mV, 100 mV (75 mV rated), 1V, 5V, and five gears |
accuracy | 2.5 mV range: ± (0 .05% * RD + 7 μ V) |
20 mV range: ± (0 .02% * RD + 10 μ V); | |
100 mV range: ± (0 .02% * RD + 10 μ V); | |
100mV … 5V range: ± (0 .02% * RD + 10 μ V) | |
capability | Output of the U <= 100mV is 1mA; |
100mv <u <= 5V with the output 10mA | |
Electric energyaccuracy |
Electric energyaccuracy | 0.05% |
voltage and current output stability | |
voltage stability | ±(0 . 01% * RD +0 .005%RG ) /min |
current stability | ±(0 . 01% * RD +0 .005%RG ) /min |
year drift | Less than 100ppm / year |
voltage andcurrent ripple output capacity | |
ripple frequency | 0 ~ 500 Hz |
pulse coefficient | per low output greater than30% |
ripple phase | The voltage and current ripple phase error is less than 0.1 degrees |
ripple accuracy | 5% |
other indicators | |
working power supply | AC 220V ±5% 50Hz |
relative humidity | 85% |
|
![]() |